1.Go to EMS >Configuration >NSS >HLR.
2.Click the button at the upper right corner.

1.On the System tab, configure the relevant parameters given in the following table.
2.Click the button to update parameters to application servers.
Sub-parameter
|
Description (Click highlight SAVE after change)
|
Recommended Value
|
CC
|
The Country Code identifies the country in which the Home PLMN is located.
|
--
|
NDC
|
The National Destination Code identifies the home PLMN.
|
--
|
Start SN
|
Identifies the beginning of local MSISDN number range.
|
--
|
End SN
|
Identifies the end of local MSISDN number range.
|
--
|
CDR Flag
|
Enable or disable HLR CDR generation.
|
Disable
|

1.Click the VPLMN tab, and then click New at the bottom of the VPLMN table.
2.In the VPLMN ID box, select an available number for the new VPLMN, and then click the button.
3.In the VPLMN Option window, configure the relevant parameters given in the following table.
4.Click the button to update parameters to application servers.
Sub-parameter
|
Description (Click highlight SAVE after change)
|
Recommended Value
|
CC
|
The Country Code (CC) which identifies the country in which the GSM VPLMN is located.
|
--
|
NDC
|
The National Destination Code (NDC) which identifies the GSM VPLMN in that country.
|
--
|
Start SN
|
This parameter identifies the beginning of a VLR number range.
|
--
|
End SN
|
This parameter identifies the end of a VLR number range.
|
--
|

1.Click the CSRR List tab to display the CSRR List table.
2.Click the hyperlinked parameter value of an available entry to open its Option window.
3.Configure the relevant parameters given in the following table, click the button to return.
4.Click the button to update parameters to application servers.
Sub-parameter
|
Description
|
Recommended Value
|
VPLMN ID
|
The CSRR list defines the roaming restriction for 256 VPLMN which corresponds to the VPLMN configured previously.
|
Enable
|
|