Enabling Notification Short Message

Top  Previous  Next

Implementation

 

hmtoggle_arrow1Configure SMPP Parameters

 

2_70_03

 

1.Go to EMS >Configuration >NSS >SMPP.

 

2.Make sure the System ID at the upper right corner displays SMPP(MSS_Pub), click the 2_035 button.

 

3.Click the hyperlinked index number of New to open an Option window.

 

4.Configure the necessary parameters given in the following table to setup the SMPP connection for the forward direction.

 

5.Click the 2_041 button to update parameters to application servers.

 

6.Repeat steps 3 to 5 to add another SMPP connection for the opposite direction.

 

Sub-parameter

Description (Click highlight SAVE after change)

Forward Connection

Reverse Connection

Link Alias

Name of the SMPP connection. Enter the PPS inquiry number which configured in PPS >SRF Parameters >SRF Number >Inquiry Number.

PPS Inquiry Number

PPS Inquiry Number

Link Type

Transport protocol of the SMPP connection.

UDP

UDP

Server Type

Specify the application type of the local SMPP entity.

Server

Client

Session Type

Specify how the local SMPP entity shall bind to the remote SMPP entity. Select bindTRX as a transceiver.

bindTRX

bindTRX

System ID

Specify the user name for the gateway to use when connecting to the remote SMPP entity. Enter PPS by default.

PPS

PPS

Password

Specify the password for the gateway to use when connecting to the remote SMPP entity. Enter 123456 by default.

123456

123456

System Type

An optional login parameter that should be set only if required by the remote SMPP entity. Enter GSM by default.

GSM

GSM

Local GTT

Specify the GTT of local SMPP entity. Enter the SMPP-SMSC and SMPP-EMSE E.164 number which configured in SCCP >Local Node.

SMPP-SMSC

SMPP-EMSE

Remote GTT

Specify the GTT of remote SMPP entity. Enter the SMPP-EMSE and SMPP-SMSC E.164 number which configured in SCCP >Local Node.

SMPP-EMSE

SMPP-SMSC

Local IP

Specify the IP address of local SMPP entity. It's not applicable here. Reserved as 0.0.0.0.

0.0.0.0

0.0.0.0

Remote IP

Specify the IP address of remote SMPP entity. It's not applicable here. Reserved as 0.0.0.0.

0.0.0.0

0.0.0.0

Session Init Timer

Specify the maximum time-out value for the time period between an application's network connection setup request and BIND request.

If the time-out value is reached, the connection is terminated. Reserved as 5.

5

5

Enquire Link Timer

Specify the minimum time-out period between the SMPP service's sending of ENQUIRE LINK requests to an application. Reserved as 10.

10

10

Inactivity Timer

Specify the maximum time-out period allowed for inactivity between an application’s request towards the SMPP service. If the time-out value is reached, the connection is terminated. Reserved as 5.

5

5

Response Timer

Specify the maximum time-out period allowed between the SMPP service sends a request to an application and a response to the request is received.

If the time-out value is reached, the connection is terminated. Reserved as 5.

5

5

Local SSN

Specify the subsystem number of local SMPP entity. Reserved as 0.

0

0

Remote SSN

Specify the subsystem number of remote SMPP entity. Reserved as 0.

0

0

Flag

Enable or disable this SMPP connection.

Enable

Enable

 

 

hmtoggle_arrow1Configure SMSC Parameters

 

1.Go to EMS >Configuration >NSS >SMSC.

 

2.Make sure the System ID at the upper right corner displays SMSC_pub, click the 2_035 button.

 

2_70_04

 

1.Click to open the SMPP tab.

 

2.Click the hyperlinked index number of New to open an Option window.

 

3.Configure the necessary parameters given in the following table.

 

4.Click the 2_041 button to update parameters to application servers.

 

Sub-parameter

Description (Click highlight SAVE after change)

Recommended Value

Link Alias

It is the same Link Alias as that in the previous SMPP configuration. Use the PPS inquiry number by default.

PPS Inquiry Number

Session Type

Specify how the local SMPP entity shall bind to the remote SMPP entity. Select bindTRX as a transceiver.

bindTRX

Service Number

Enter the PPS balance transfer service number which configured in PPS >SRF Parameters >SRF Number >Inquiry Number.

PPS Inquiry Number

DCS

Data Coding Scheme. Reserved as smpp7def8.

smpp7def8

Platform ID

The served MSC platform. Reserved as Ignore.

Ignore

Time to Live

Define the maximum duration of a pending message which should be kept in sending array till reaches the called subscriber.  Messages can't send out in the validity period will be deleted. Unit is second. Reserved as 18 hours.

64800

Manipulation Flag

Enable or disable CLI Manipulation in XAPP setting. Reserved as Disable.

Disable

TON

Indicate Type of Number for destination. Reserved as Unknown.

Unknown

NPI

Indicate Numbering Plan Indicator for destination. Reserved as Unknown.

Unknown

 

 

hmtoggle_arrow1Customize Notification Short Message Contents

 

1.Go to EMS >Configuration >NSS >PPS.

 

2.Make sure the System ID at the upper right corner displays PPS_pub, click the 2_035 button.

 

2_48_20

 

1.Click to open the Service Control >Prompt Resolution tab.

 

2.Click the hyperlinked index number 0 to open the configuration window.

 

3.Configure the necessary parameters given in the following table.

 

4.Click the 2_041 button to update parameters to application servers.

 

Sub-parameter

Description (Click highlight SAVE after change)

Optional Values

Currency Resolution

Specify the number of decimal place in the PPS notification short message balance display and audio prompt.

For example, balance=1234:

n1=1234, n10=123.4, n100=12.34

n1

n10

n100

Date Format

Specify date format in PPS notification short message and audio prompt.

YYYYMMDD

DDMMYYYY

MMDDYYYY

Currency Symbol Position

Specify the position of the currency symbol in PPS notification short message.

At the front of the balance: $5

At the rear of the balance: 5$

Front

Rear

 

2_48_21

 

1.Click to open the Service Control >SMS Sentence tab.

 

2.Click the hyperlinked index number of the sentence wanted to change to open the configuration window.

 

3.Edit the sentence in the Language x Content line, click highlighted SAVE when it's done.

 

4.Click the 2_041 button to update parameters to application servers.

 

 

hmtoggle_arrow1Customize Notification Short Message Attributes

 

1.Go to EMS >Configuration >NSS >PPS.

 

2.Make sure the System ID at the upper right corner displays PPS_pub, click the 2_035 button.

 

2_48_31

 

1.Click to open the Service Control >COS tab.

 

2.Click the hyperlinked index number to open an existing COS table, or click New to create a new COS table.

 

3.In the Short Message Notification & Inquiry table, configure the necessary parameters given in the following table.

 

4.Click the 2_041 button to update parameters to application servers.

 

Sub-parameter

Description (Click highlight SAVE after change)

Optional Values

Short Message Notification

Attributes of notification short message

--

Successful Recharge

Enable or disable feedback short message of recharge result.

Enable

Disable

Account Inquiry

Enable or disable feedback short message of balance inquiry.

Expiration

Enable or disable notification short message sending when an account is going to expire.

(Days) Before Expiration

Define the sending days before account expires.

0 - 32 days

Insufficient Balance

Enable or disable notification short message sending when the account's balance is too low.

Enable

Disable

When Balance Reaches

Define the low balance level to send notification short message. Unit is the minimum currency unit.

0 - 65535

Clear Balance

Enable or disable notification short message sending when the balance is cleared from an expired account.

Enable

Disable

CAP Plan Upgrade

Enable or disable notification short message sending when the predefined CAP threshold is about to grade up.

Overdraw Balance

Enable or disable notification short message sending when the account takes out an overdraft to pay for the charge.

Rent Charge

Enable or disable notification short message sending when rent is charged.

F&F Registration

Enable or disable notification short message sending when Friends and Family Number plan is registered.

F&F Suspended

Enable or disable notification short message sending when Friends and Family Number plan is suspended.

F&F Exceed Threshold

Enable or disable notification short message sending when Friends and Family Number plan exceeded the free voice call duration or free SMS threshold.

F&F Removed

Enable or disable notification short message sending when Friends and Family Number plan is removed.

Inquiry by Short Message

Attributes of inquiry short message

--

Charge Flag

Enable or disable charge for inquiry short message.

Charge

Free

Free Inquiry per Day

Define the quantity of free inquiry short messages on a daily basis if charge flag is enabled.

0 - 128

 

 

 

See Also

 

Configure Tariff

 

Manage PPS Subscribers

 

 

Return to

 

Tasks List

 

Elements List

 

 

 

 

 

2.48.2