Files
svc.ems/omc/bin/mib/LGC-SS-MNP-MIB.my

379 lines
8.8 KiB
Plaintext

--
-- LGC-SS-MNP-MIB.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 7.0 Build 209
-- Monday, September 13, 2010 at 17:59:41
--
LGC-SS-MNP-MIB DEFINITIONS ::= BEGIN
IMPORTS
lgcSS, DisplayString16, RowStatus, DisplayString
FROM LGC-MIB
Opaque, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI;
-- 1.3.6.1.4.1.1373.2.3.3.7
mnp MODULE-IDENTITY
LAST-UPDATED "200706291606Z" -- June 29, 2007 at 16:06 GMT
ORGANIZATION
"LGC Wireless"
CONTACT-INFO
"lcrd
lcrdsupport@lgcwireless.com"
DESCRIPTION
"Description."
REVISION "200706051219Z" -- June 05, 2007 at 12:19 GMT
DESCRIPTION
"This is the first release version of the MSC MIB"
::= { mss 7 }
--
-- Type definitions
--
AvailStateChoices ::= INTEGER
{
inTest(0),
failed(1),
powerOff(2),
offLine(3),
onLine(4),
dependency(5),
degraded(6),
notInstalled(7)
}
--
-- Node definitions
--
-- Node definitions
--
-- The MIB module for WXC2.
-- 1.3.6.1.4.1.1373.1.3
-- 1.3.6.1.4.1.1373.2.3
wxc2 OBJECT IDENTIFIER ::= { lgcSS 3 }
-- 1.3.6.1.4.1.1373.1.3.3
-- 1.3.6.1.4.1.1373.2.3.3
mss OBJECT IDENTIFIER ::= { wxc2 3 }
-- 1.3.6.1.4.1.1373.2.3.3.7.1
heartbeat OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description."
::= { mnp 1 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2
-- 1.3.6.1.4.1.1373.2.3.3.7.2
parameter OBJECT IDENTIFIER ::= { mnp 2 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1
system OBJECT IDENTIFIER ::= { parameter 1 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.1
flag OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:MNP Flag
Remark:Enable or disable MNP (Mobile Number Portability) function."
::= { system 1 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.2
nPLRNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:NPLR Address
Remark:The E.164 node address of the NPLR (Number Portability Location Register)."
::= { system 2 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.3
routingNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:Routing Number
Remark:A specific number which is part of the routing information, used by the network to route the call and the non-call related signaling messages."
::= { system 3 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.4
routingMethod OBJECT-TYPE
SYNTAX INTEGER
{
direct(1),
indirect(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:Routing Method
Remark:For every call or non-call related transaction initiated from local network, the MSC can select one of the two following routing conventions:<UL><LI>Direct = Route the calls directly from the PLMN to the ported subscriber's network.</LI><LI>Indirect = Route the calls from the PLMN to the ported subscriber's subscription network via the number range holder.</LI></UL>"
::= { system 4 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.5
rNPosition OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:RN Position
Remark:The routing number will be attached to the called number in the portability database. <br>This parameter specifies the digit position of the called number to append the routing number."
::= { system 5 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.6
type OBJECT-TYPE
SYNTAX INTEGER
{
srf(0),
ansiIn(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name:MNP Solution
Remark:Select a solution for call related signaling in the ETSI MNP-standard:<UL><LI>MNP-SRF = Mobile Number Portability Signaling Relay Function</LI><LI>ANSI IN = American National Standard Institute Intelligent Network</LI></UL>"
::= { system 6 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.7
systemCommand OBJECT-TYPE
SYNTAX INTEGER { saveSubsData(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Description."
::= { system 7 }
-- 1.3.6.1.4.1.1373.2.3.3.7.2.1.8
importSubs OBJECT-TYPE
SYNTAX Opaque (SIZE (7))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Hidden Flag:Yes
OPAQUE DECODE RULE:
[unit]operation[u]00.0-00.7[u]select
[v]1[opt]Send
[v]2[opt]Reading
[v]3[opt]Succeed
[v]4[opt]Failed
[unit]Imported subs.[u]01.0-03.7[u]input
[v]toDec-high-0
[unit]Loaded subs.[u]04.0-06.7[u]input
[v]toDec-high-0"
::= { system 8 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.1
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2
localPrefix OBJECT IDENTIFIER ::= { parameter 2 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.1.4
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1
localPrefixTable OBJECT-TYPE
SYNTAX SEQUENCE OF LocalPrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { localPrefix 1 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.1.4.1
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1.1
localPrefixEntry OBJECT-TYPE
SYNTAX LocalPrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"level:1"
INDEX { localIndex }
::= { localPrefixTable 1 }
LocalPrefixEntry ::=
SEQUENCE {
localIndex
INTEGER,
localTitle
OCTET STRING,
localPrefixNumber
OCTET STRING,
localRowStatus
RowStatus
}
-- Route Selection RZS Index
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.1
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1.1.1
localIndex OBJECT-TYPE
SYNTAX INTEGER (0..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Index
Remark:Local prefix index number ranges from 0 to 31."
::= { localPrefixEntry 1 }
-- Title
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.3
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1.1.2
localTitle OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Title
Remark:Local prefix name for identification purpose only."
::= { localPrefixEntry 2 }
-- Trunk Group
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.5
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1.1.3
localPrefixNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Prefix
Remark:Specify prefix of E.164 numbers using in the local network."
::= { localPrefixEntry 3 }
-- Row Status
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.11
-- 1.3.6.1.4.1.1373.2.3.3.7.2.2.1.1.4
localRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes"
::= { localPrefixEntry 4 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.2
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3
portablePrefix OBJECT IDENTIFIER ::= { parameter 3 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.1.4
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1
portablePrefixTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortablePrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Description."
::= { portablePrefix 1 }
-- 1.3.6.1.4.1.1373.1.3.3.2.2.1.4.1
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1.1
portablePrefixEntry OBJECT-TYPE
SYNTAX PortablePrefixEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"level:1"
INDEX { portableIndex }
::= { portablePrefixTable 1 }
PortablePrefixEntry ::=
SEQUENCE {
portableIndex
INTEGER,
portableTitle
DisplayString16,
portablePrefixNumber
OCTET STRING,
portableRowStatus
RowStatus
}
-- Route Selection RZS Index
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.1
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1.1.1
portableIndex OBJECT-TYPE
SYNTAX INTEGER (0..127)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Index
Remark:Portable prefix index number ranges from 0 to 127."
::= { portablePrefixEntry 1 }
-- Title
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.3
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1.1.2
portableTitle OBJECT-TYPE
SYNTAX DisplayString16
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Title
Remark:Portable prefix name for identification purpose only."
::= { portablePrefixEntry 2 }
-- Trunk Group
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.5
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1.1.3
portablePrefixNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes Name:Prefix
Remark:Specify prefix of E.164 numbers that can be ported among networks."
::= { portablePrefixEntry 3 }
-- Row Status
-- 1.3.6.1.4.1.1373.2.3.3.2.2.1.4.1.11
-- 1.3.6.1.4.1.1373.2.3.3.7.2.3.1.1.4
portableRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Key Parameter:Yes"
::= { portablePrefixEntry 4 }
END
--
-- LGC-SS-MNP-MIB.my
--